.. _`captures`: Capturing of the stdout/stderr output ========================================================= Default stdout/stderr/stdin capturing behaviour --------------------------------------------------------- During test execution any output sent to ``stdout`` and ``stderr`` is captured. If a test or a setup method fails its according captured output will usually be shown along with the failure traceback. (this behavior can be configured by the ``--show-capture`` command-line option). In addition, ``stdin`` is set to a "null" object which will fail on attempts to read from it because it is rarely desired to wait for interactive input when running automated tests. By default capturing is done by intercepting writes to low level file descriptors. This allows to capture output from simple print statements as well as output from a subprocess started by a test. .. _capture-method: Setting capturing methods or disabling capturing ------------------------------------------------- There are three ways in which ``pytest`` can perform capturing: * ``fd`` (file descriptor) level capturing (default): All writes going to the operating system file descriptors 1 and 2 will be captured. * ``sys`` level capturing: Only writes to Python files ``sys.stdout`` and ``sys.stderr`` will be captured. No capturing of writes to filedescriptors is performed. * ``tee-sys`` capturing: Python writes to ``sys.stdout`` and ``sys.stderr`` will be captured, however the writes will also be passed-through to the actual ``sys.stdout`` and ``sys.stderr``. This allows output to be 'live printed' and captured for plugin use, such as junitxml (new in pytest 5.4). .. _`disable capturing`: You can influence output capturing mechanisms from the command line: .. code-block:: bash pytest -s # disable all capturing pytest --capture=sys # replace sys.stdout/stderr with in-mem files pytest --capture=fd # also point filedescriptors 1 and 2 to temp file pytest --capture=tee-sys # combines 'sys' and '-s', capturing sys.stdout/stderr # and passing it along to the actual sys.stdout/stderr .. _printdebugging: Using print statements for debugging --------------------------------------------------- One primary benefit of the default capturing of stdout/stderr output is that you can use print statements for debugging: .. code-block:: python # content of test_module.py def setup_function(function): print("setting up", function) def test_func1(): assert True def test_func2(): assert False and running this module will show you precisely the output of the failing function and hide the other one: .. code-block:: pytest $ pytest =========================== test session starts ============================ platform linux -- Python 3.x.y, pytest-6.x.y, py-1.x.y, pluggy-0.x.y cachedir: $PYTHON_PREFIX/.pytest_cache rootdir: $REGENDOC_TMPDIR collected 2 items test_module.py .F [100%] ================================= FAILURES ================================= ________________________________ test_func2 ________________________________ def test_func2(): > assert False E assert False test_module.py:12: AssertionError -------------------------- Captured stdout setup --------------------------- setting up ========================= short test summary info ========================== FAILED test_module.py::test_func2 - assert False ======================= 1 failed, 1 passed in 0.12s ======================== Accessing captured output from a test function --------------------------------------------------- The ``capsys``, ``capsysbinary``, ``capfd``, and ``capfdbinary`` fixtures allow access to stdout/stderr output created during test execution. Here is an example test function that performs some output related checks: .. code-block:: python def test_myoutput(capsys): # or use "capfd" for fd-level print("hello") sys.stderr.write("world\n") captured = capsys.readouterr() assert captured.out == "hello\n" assert captured.err == "world\n" print("next") captured = capsys.readouterr() assert captured.out == "next\n" The ``readouterr()`` call snapshots the output so far - and capturing will be continued. After the test function finishes the original streams will be restored. Using ``capsys`` this way frees your test from having to care about setting/resetting output streams and also interacts well with pytest's own per-test capturing. If you want to capture on filedescriptor level you can use the ``capfd`` fixture which offers the exact same interface but allows to also capture output from libraries or subprocesses that directly write to operating system level output streams (FD1 and FD2). The return value from ``readouterr`` changed to a ``namedtuple`` with two attributes, ``out`` and ``err``. If the code under test writes non-textual data, you can capture this using the ``capsysbinary`` fixture which instead returns ``bytes`` from the ``readouterr`` method. If the code under test writes non-textual data, you can capture this using the ``capfdbinary`` fixture which instead returns ``bytes`` from the ``readouterr`` method. The ``capfdbinary`` fixture operates on the filedescriptor level. To temporarily disable capture within a test, both ``capsys`` and ``capfd`` have a ``disabled()`` method that can be used as a context manager, disabling capture inside the ``with`` block: .. code-block:: python def test_disabling_capturing(capsys): print("this output is captured") with capsys.disabled(): print("output not captured, going directly to sys.stdout") print("this output is also captured")