summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authormandyshen <mandyshen@google.com>2019-04-03 17:32:13 +0800
committermandyshen <mandyshen@google.com>2019-04-09 14:11:28 +0800
commitd0132ea52d568fde56147fced01fac6fada2e464 (patch)
treed3151e3aec7a299a76282fc8f1e3531a5bcd3010
parentb81340e07f8c3b68e568d3573619a069b427dc6f (diff)
downloadbonito-d0132ea52d568fde56147fced01fac6fada2e464.tar.gz
Revise emergency threshold for UI overheat warning.
Emergency threshold of thermal hal is only used for UI warning. This value will set based on shutdown threshold minus 4degC. Bug: 129809147 Test: UI overheat waning can pop-out when crossing emergency threshold. Change-Id: Iecc51ba463b943db3bab35147f524defa6ba0c24
-rw-r--r--thermal_info_config_bonito.json2
-rw-r--r--thermal_info_config_sargo.json2
2 files changed, 2 insertions, 2 deletions
diff --git a/thermal_info_config_bonito.json b/thermal_info_config_bonito.json
index 3cbf6341..d630af4e 100644
--- a/thermal_info_config_bonito.json
+++ b/thermal_info_config_bonito.json
@@ -199,7 +199,7 @@
43.0,
48.0,
50.0,
- 51.0,
+ 54.0,
58.0
],
"HotHysteresis":[
diff --git a/thermal_info_config_sargo.json b/thermal_info_config_sargo.json
index fc59cbd8..af208cba 100644
--- a/thermal_info_config_sargo.json
+++ b/thermal_info_config_sargo.json
@@ -199,7 +199,7 @@
43.0,
46.0,
47.0,
- 49.0,
+ 51.0,
55.0
],
"HotHysteresis":[