Revise emergency threshold for UI overheat warning.
Emergency threshold of thermal hal is only used for UI warning.
This value will set based on shutdown threshold minus 4degC.
Bug: 129809147
Test: UI overheat waning can pop-out when crossing emergency threshold.
Change-Id: Iecc51ba463b943db3bab35147f524defa6ba0c24
-rw-r--r-- | thermal_info_config_bonito.json | 2 | ||||
-rw-r--r-- | thermal_info_config_sargo.json | 2 |
2 files changed, 2 insertions, 2 deletions
diff --git a/thermal_info_config_bonito.json b/thermal_info_config_bonito.json index 3cbf6341..d630af4e 100644 --- a/thermal_info_config_bonito.json +++ b/thermal_info_config_bonito.json @@ -199,7 +199,7 @@ 43.0, 48.0, 50.0, - 51.0, + 54.0, 58.0 ], "HotHysteresis":[ diff --git a/thermal_info_config_sargo.json b/thermal_info_config_sargo.json index fc59cbd8..af208cba 100644 --- a/thermal_info_config_sargo.json +++ b/thermal_info_config_sargo.json @@ -199,7 +199,7 @@ 43.0, 46.0, 47.0, - 49.0, + 51.0, 55.0 ], "HotHysteresis":[ |